No.1 Xinle Road, Chang'an, Dongguan, China

Custom Magnetic Connectors

CTP Yongtan develops custom magnetic connectors around your device’s pinout, available space and the way users connect and disconnect it.

Discuss Your Connector Project

Contact Layout and Mating Geometry

Contact Count and Pinout

Start by assigning a function to each contact. Identify the power and ground paths, any signal lines, and the electrical load the interface needs to carry. If you already have a pinout, mark any positions that need to stay fixed so we can review the remaining layout around them.

Our customization guide covers magnetic connectors and cable assemblies with 1 to 40 contacts. We review the feasible contact count and spacing against your electrical requirements and the room available on the mating face.

Interface Shape and Contact Position

We develop round, rectangular, oblong and linear mating interfaces. A dimensioned view of both mating faces helps us review where each contact lands and how much space remains for magnets and alignment features. If one half sits inside a recess, show how the other half approaches and seats against it.

If you already know the contact count or interface shape you need, compare our magnetic connector options.

Magnet Placement and Holding Force

Magnet Position, Polarity and Keying

Magnet position and polarity affect how the two halves come together. We review them alongside the contact layout and any physical keying features that guide the connector into the intended position. If the interface needs to mate in more than one orientation, identify which contacts should connect in each position so we can review the electrical mapping.

Holding Force and Release

Describe how the connection should hold during normal use and how the user should release it. A handheld device might need to stay seated while its dock is moved, then lift out easily from one edge. That lift can load the interface differently from a straight pull. If you have a force target, include the pull direction and any test conditions used to define it.

Housing, Mounting and Device Integration

Housing Fit and Mounting

Show where the connector sits in the device, how it is secured, and how much depth is available behind the mounting surface. An enclosure drawing or section view helps us review the opening, surrounding components and assembly access. Our Dongguan manufacturing operations include housing molding and connector assembly.

Termination and Supply Scope

Specify whether you need one connector half or a matched pair, and show how the terminals will connect to the device circuit. Include the location of the board or wire connection and any routing constraints that affect assembly.

For a finished lead with a specified interface at the opposite end, see our custom magnetic cables. If the connector needs to be supplied with a PCB, flexible printed circuit (FPC) or internal harness as one assembly, explore our integrated connector modules.

Magnetic Connector Design Scenarios

Compact Wearable Charging Dock

In a low-profile smartwatch or smart ring dock, the charging contacts need to line up as the device settles into place. Start by defining where the dock locates the device and how much space is available beneath the seating surface. Those dimensions guide the position of the contacts and magnets.

Detachable Industrial Power and Signal Interface

For a mobile robot that approaches a dock from slightly different positions, define how much offset the mating interface is expected to accommodate. If the connector carries power and signals, identify which contacts handle each function and the expected electrical loads. Include how often the interface mates and how it disengages when the robot leaves the dock.

Sample Fit and Performance Checks

We use engineering samples to check fit and performance. With the sample installed in the device or a representative fixture, check whether the two halves seat fully, the contacts line up, and the interface releases in the intended direction.

Depending on the design and conditions of use, our laboratory can measure mating and pull forces, run connection-cycle tests, and check contact resistance, current and temperature rise. We agree on the relevant checks with you and use the approved configuration to set the production drawing and inspection criteria. See our connector testing capabilities.

Frequently Asked Questions

Can you review a design around an existing mating half?

Yes. Send a drawing or a sample of the existing half, along with any known details about contact positions, magnet polarity and alignment features. We’ll review the electrical and mechanical requirements of the pair before confirming compatibility.

How can I describe holding force before I have a numeric target?

Tell us when the connection needs to stay engaged and how you want the user to release it. If you’re replacing an existing connector, describe when it comes loose or feels difficult to detach. That gives us a starting point for discussing a force target and checking it on a sample.

When can you confirm sample and delivery dates?

We confirm sample and delivery dates after reviewing the design, materials and approval steps. Include any prototype or production milestones with your inquiry so we can consider them during the review.

What to Send for a Design Review

Share the information you have, and tell us which parts of the design are already fixed and where there’s room to make changes.

  • A drawing or sketch showing the space available on both sides of the interface and any mounting constraints.
  • A pinout that identifies each contact and its function.
  • Electrical requirements, including operating voltage, current and any signal requirements.
  • Use conditions, including how the connector mates and releases, how often it connects, and any relevant environmental exposure.
  • Target quantities for samples and production, if available.

If you’ve specified a holding force, a preferred release direction or a target number of mating cycles, include those details and any conditions the design needs to meet.

Discuss Your Connector Project
Scroll to Top